Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. In most cases like this, replacing the trippers is the solution. Theres an issue with the wiring between the circuit breaker and the timer. The capacitor for the motor may be bad. My timer doesnt seem to be working or my pump in either speed. },
Is the ON tripper all the way pushed onto the dial? I am using the breaker to turn on and off the pool pump. Voltage is 243, frequency is 60hz. Gently tighten the screws to securely hold the dogs in place. The pump worked perfectly before I unscrewed it. "@type": "BlogPosting",
Replaced timer motor on a T10404R Now time is running fast about 2 hrs. did i do something incorrectly? Did I wire it incorrectly or did I just get a bad timer? Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Still no luck. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. 3. I have an intermatic T20004R and my timer is working because it is keeping the correct time. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. Pools are not cheap! You need extreme care in this next step. I bought a new timer and replace the T104 timer clock. It randomly loses the time that it is set to. For Sale: 2 beds, 2 baths 1152 sq. Help! Put them back on and tighten them. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. This product is certified by Amazon to work with Alexa. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. I replaced the pump and still nothing is moving. Your email address will not be published. I have a PF1112T. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Hello. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. Did you find the issue? Is it toast ? Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. I have a Model T104P and have a new green on tripper attached. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. the trippers are even slightly damaged the timer won't work correctly. Move the switch and see that they separate when off, and come together when on. It is not warped in any way. This morning the customer said it wasn't turning off. Does this give you a better idea of the problem? There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Do not remove the screws from the trippers. You can replace the entire mechanism or the gears. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Below is a breakdown of how to wire different Intermatic timer models. Thanks in advance! That will do it. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. They are little ants that just came. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. Any suggestions as to how to test clock feed? document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. Now Im having to turn my pool pump on and off manually. Hi, Davy, seeing lots of complaints here. Electricity is dangerous and can kill you if you dont know what youre doing. Hi Tom, sure you can spray some 3-in-1 or wd-40 on the motor gears, just depress the tab at 12 oclock and pop out the mechanism, to target the oil onto the gears. No matter what caused the issue, there is typically an easy fix! My intermatic timer is about two years old as well. Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. The yellow clock face should sit down in the timer. Hey there! Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. Hi Bev, seems legit to me! I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. First time pool owner, Pool timer and trippers not working properly! Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. Turn the metal bar until it contacts one of two plastic side tabs. it could also be a failing breaker, but that would be a last resort. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. If you dont have the voltage here you have an issue with either the wiring or the breaker. by pool co. , so wondered about the cost. Timer not tripping pump on. Confused. Take them off and inspect them and look for twists in them. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Any ideas why its doing that? Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Move the start and stop pins to appropriate times for swimming pool filter operation. I need to replace a timer for my pool vacuum. Here are some pictures. Thank you. Okay, so lets move on to the Intermatic Pool Timer troubleshooting and figure out why your timer is not working. You most likely just need to now set the pins and the clock and your timer will work. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. The other gears move very slowly, and appear to not move at all, except for one I believe? VIDEO TOUR. To do this, pull the yellow-faced time dial (clockface) toward you. The on/off pins are tight and pretty new stillany thoughts? So what would be the problem? If all looks well, and the gears are still not turning, you may need to replace the mechanism. Manual switch works my aerator. If you cant, is the manual switch stuck or jammed? However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. I noticed one thing that the power from the breaker is going into the control panel. Articles and resources for swimming pool owners and DIYers. Take a good look at the position of the pins and write down the locations. These clocks determine when your pool pump turns on, and how long it runs. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Replaced complete new timer assuming 5 years perfect service probably wore it out. It would not reset itself and could not get power back to the timer. OPEN TODAY, 12PM TO 3PM. My intermatic pool timer will not automatically turn on. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. You dont have two OFF trippers, right? Hi, then the power for the clock must be from the switch, and not from the breaker? Read full answer 2/14/2023 3:20:07 AM Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. A recent power outage will cause the timer to stop working. Rich. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. Lately, the timer mechanism on my old T104R does not move. Save my name, email, and website in this browser for the next time I comment. Check that the breaker is firmly pushed onto the bar, and is not loose. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). the ground wire? The 2,810 sq. First, verify the power is turned off at the breaker panel. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. Hi, I got the same problem as my clock not working. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. The terminals on the wires aren't tight. Pool pump timers can last up to 20 years, depending on the model. Recently i just notice my T104R timer a bit noisier than usual. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. 4 Beds. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. As you release the dial, you will feel the gears engage. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. I visually checked the clock motor and it was good. Could also be grit or insects inside of the gears of the clock motor. "@type": "ImageObject",
I also dont see any ants or other insects. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Hi, hope you are doing well. Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. BUILT BY HAND IN QUEENS, NYC. Not two OFF trippers?
Was Joseph James Deangelo Ever A Suspect,
2020 Pga Tour Player Residence List,
Knobbe Cattle Company West Point, Ne,
Articles P